Everything SnapRAID knows about your array comes from one plain-text file. This chapter writes the lab's config line by line; the same lines, with real mount points, are a working config for a real array. The full file is also in examples/snapraid.conf.

The lab's config

parity /home/hatch/workspace/snapraid-lab-work/parity/snapraid.parity
content /home/hatch/workspace/snapraid-lab-work/disk1/snapraid.content
content /home/hatch/workspace/snapraid-lab-work/disk2/snapraid.content
data d1 /home/hatch/workspace/snapraid-lab-work/disk1/
data d2 /home/hatch/workspace/snapraid-lab-work/disk2/
exclude /snapraid.content
exclude /snapraid.parity

On a real machine the paths would be mount points — /mnt/disk1/, /mnt/disk2/, /mnt/parity/ — and the shape is identical. Take the lines in turn.

parity — where the recovery information lives

parity /mnt/parity/snapraid.parity

One line names the parity file. The parity disk must have room for as much parity as the largest data disk holds data — parity grows block for block with the fullest data disk, not with the total. SnapRAID extends the file as the array grows; a parity disk that fills up stops a sync, it does not corrupt anything.

content — the index, in several copies

content /mnt/disk1/snapraid.content
content /mnt/disk2/snapraid.content

One line per copy. The rules SnapRAID enforces, and the lab met immediately:

  • at least two copies;
  • on different disks from each other;
  • a copy may live on a data disk (normal) but never only on the parity disk's device.

Transcript t12 shows status refusing a config whose content copies share a disk: "You must have at least 2 'content' files in different disks." Put a copy on every data disk. If a disk dies, its copy dies with it and the survivors carry on — chapter 7's whole-disk recovery ran on exactly that.

data — the disks being protected

data d1 /mnt/disk1/
data d2 /mnt/disk2/

Each data disk gets a short name (d1, d2, or anything you like — names appear in reports and in fix -d later) and its root path, with a trailing slash. Disks can be different sizes, different filesystems, already full of files. Order matters only for readability.

exclude — what to leave out

exclude /snapraid.content
exclude /snapraid.parity

Patterns are relative to the data disk's root. Keep SnapRAID's own files out of the array, and exclude the things parity cannot help and only churns on: caches, temporary downloads, a torrent client's scratch folder. Every excluded file is a file with no protection — exclude by temperament, not by hope. The manual lists further options (include, per-disk excludes, block_size, autosave for very large arrays); defaults serve until you have a reason.

The rules the program enforces

SnapRAID checks the config against the hardware before it does anything, and refuses — loudly, with DANGER! — when the array cannot protect what it claims to. The lab met three of these guards:

Guard Message (abridged) Transcript
Two members on one device "Disks '...' and '...' are on the same device." t12
Content copies not spread out "You must have at least 2 'content' files in different disks." t12
A parity file smaller than the array expects "One or more the parity files are smaller than expected!" t11

Treat these refusals as the program doing its job. In particular the second and third are what stand between you and syncing happily over an unmounted disk — the classic way to destroy an array with its own protection tool. Chapter 14 works through each.

Check: a config is accepted when any read-only command runs clean against it:

$ snapraid -c snapraid.conf status
SnapRAID status report:
...
No error detected.

The one-sentence version

Name one parity file, spread content copies across the data disks, list the data disks with short names, exclude SnapRAID's own files — and let the program's refusals teach you the rest.