Skip to content

Limits

The standing rule of this series: the limits in plain sight. SnapRAID's follow directly from its one design decision — snapshot parity — plus a few from being a small, single-purpose tool.

Not a backup

Say it until it is boring. SnapRAID has no history: one protected state, the last sync. It cannot answer "the file as it was last month", "the folder I deleted last week and synced over", fire, theft, flood, or malware that encrypts the array and gets synced. Files you cannot re-obtain need a backup — a separate copy, ideally elsewhere — whether or not SnapRAID is also protecting the shelf.

Blind between syncs

New and changed files are unprotected until the next sync, and a disk that dies in that window takes the unsynced changes with it. Worse, a file corrupted in that window can be synced as-is if the corruption also touched size or timestamp in a way that looks like an edit — check and scrub are the counterweight, and they only run when scheduled.

Deletion is protected only until it isn't

Chapter 7's law: an accidental deletion is recoverable up to the next sync, and permanently gone after it. Every automation decision in chapter 9 exists because of this limit. There is no undelete fairy beyond that line.

Built for big, still files

Small files that change constantly are the worst fit: sync re-reads and re-parities churn, the content file grows with file count, and the protection gap between syncs covers most of the file's life. A home directory, a mail spool, a database — protect those with backups and snapshots, not SnapRAID.

Whole disks at a time, single machine

  • A failure bigger than your parity count loses the failed disks' files (only those — survivors are untouched, but the loss is total for what failed).
  • The array lives on one machine. It does not replicate, fail over, or serve anything; it is protection, not availability. A dead machine means a working array you cannot reach until the machine is fixed.
  • Recovery speed is bounded by reading the surviving disks end to end. On large disks that is most of a day, during which (on single parity) one more bad block is a loss. Chapter 8's second parity is priced against this window.

It trusts its config and its operator

SnapRAID refuses arrays it can prove are wrong (chapter 4), but it cannot prove a mount is the right disk, that a sync is well-timed, or that you read the diff. It is a sharp tool with good guards, worked by hand or by a schedule a human set up. The guards stop the known traps; the operator is the guard for the rest.

The one-sentence version

SnapRAID gives a few big quiet disks an excellent answer to "one of them died or rotted" — and no answer at all to history, disaster, or constant change, so pair it with a backup and a schedule and know which job is whose.